MultiPASS MP730/MP700 Chapter 3: Assembly and Disassembly
(7) Remove the screw (d), and detach the grounding cable.
(8) Disconnect the connector JFBM3 of sensor board sub PCB.
(9) Push the button, and open the flatbed ass'y.
(10) Remove the 2 screws (e), and detach the SPCNT cover.
(11) Disconnect the connector JCS1 of the SPCNT board.
(12) Remove the joint shaft. Be sure to free the claw while doing so.
(13) Remove the torsion bars.
(14) Remove the flatbed ass'y.
Joint shaft
d
Flatbed ass'y
Torsion bar
e
Button
SPCNT cover
Figure 3-13 Contact Sensor 3
3-15