Enter the Console Server's IP address (or network name).
Enter the Server TCP Port number that matches the port you have configured for the serial
device on the remote Console Server. Ensure this port isn't blocked by a firewall.
o Telnet RFC2217 mode is configured by default so the range of port numbers available on
a 16-port console server would be 5001-5016
o Alternately check RAW mode (4001- 4048 on a 48 port console server)
o Select Encrypted to enable SSL/TLS encryption of the data going to the port. You will
need to enter a Password
Select the starting COM port (COM1 to COM4096).
Specify the number of ports you want to add. Sequential port numbers will be assigned
automatically. If a COM port # is already being used by other applications, that # will be skipped.
Click OK to add the specified COM ports.
To configure a COM port you have created, simply click on the desired COMx label in the left
hand menu tree.
In the Properties window you can edit the IP address or TCP Port to be used to connect to that
COM port.
You can then configure the COM port in the Connection and Advanced windows: