User Guide

5.2 Open-window function

living connect® features an Open-window function, which
closes the valve if the room temperature is falling
dramatically, thus reducing the heat loss.
The heat is turned off in the entire room for up to 30
minutes, before living connect® returns to its original
settings.
When Open-window has been activated, the function is
quarantined for 45 minutes.
Note! Be aware that the Open-window function will be
affected, if curtains or furniture is covering living connect®,
thus preventing it from detecting the decreasing temperature.

5.3 Automatic valve exercising

To keep the radiator valve functional and at its best, living connect® automatically exercises the
valve every Thursday at approx. 11:00 hrs by opening it fully and then return to normal setting.

6. Safety precautions

The thermostat is not intended for children and must not be used as a toy.
Do not leave packaging materials where children may be tempted to play with them, as this is
extremely dangerous.
Do not attempt to dismantle the thermostat as it contains no user-serviceable parts. If error code
E1, E2 etc. is shown in the display or other defects appear, please return the thermostat to the
distributor.

7. Disposal

The thermostat must be disposed of as electronic waste.