BHT-1170BWB-CE / BHT-1171BWB-CE

7.1 System Errors

The error messages that display on the screen and the causes and countermeasures to be taken if an error occurs
when the power is turned ON or while running a program are shown below. The error message is displayed by the
application language in the specific country.
Message
146
BHT Response
The beeper sounds 5
System program
times (each beep lasts
abnormality
for 0.1 seconds) and
then the power turns
OFF.
The BHT displays a
The battery voltage has
warning for
dropped to a level that
approximately 2 seconds
requires charging or
while sounding the
battery replacement
beeper 3 times (each
when turning the BHT
beep lasts for 0.1
ON, OFF or while
seconds) before
running a program.
returning to its normal
operational status.
The beeper sounds 5
The battery voltage has
times (each beep lasts
dropped to a level that
for 0.1 seconds) and
prevents BHT operation
then the power turns
when turning the BHT
OFF. Depending on the
ON, OFF or while
battery consumption
running a program.
status, the beeper may
not sound 5 times.
Cause
Countermeasure
Notify the system
administrator.
The battery will soon
need charged.
Replace or charge the
battery promptly.
If the BHT is left with
the battery discharged,
data including files and
settings stored in the
RAM may be lost.
Replace or charge the
battery immediately. If
the BHT is left with the
battery discharged,
data including files and
settings stored in the
RAM may be lost.