Display System Environmental Sensors - IBM H80 User Manual

660 series enterprise server
Hide thumbs Also See for H80:
Table of Contents

Advertisement

v List Fileset Dependents
v List Files Included in a Fileset
v List File Owner by Fileset

Display System Environmental Sensors

This service aid displays the environmental sensors implemented on a CHRP system.
The information displayed is the sensor name, physical location code, literal value of
the sensor status, and the literal value of the sensor reading.
The sensor status can be any one of the following:
v Normal – The sensor reading is within the normal operating range.
v Critical High – The sensor reading indicates a serious problem with the device. Run
diagnostics on sysplanar0 to determine what repair action is needed.
v Critical Low – The sensor reading indicates a serious problem with the device. Run
diagnostics on sysplanar0 to determine what repair action is needed.
v Warning High – The sensor reading indicates a problem with the device. This could
become a critical problem if action is not taken. Run diagnostics on sysplanar0 to
determine what repair action is needed.
v Warning Low – The sensor reading indicates a problem with the device. This could
become a critical problem if action is not taken. Run diagnostics on sysplanar0 to
determine what repair action is needed.
v Hardware Error - The sensor could not be read because of a hardware error. Run
diagnostics on sysplanar0 in problem-determination mode to determine what repair
action is needed.
v Hardware Busy – The system has repeatedly returned a busy indication, and a
reading is not available. Try the service aid again. If the problem continues, run
diagnostics on sysplanar0 in problem-determination mode to determine what repair
action is needed.
This service aid can also be run as a command. You can use the command to list the
sensors and their values in a text format, list the sensors and their values in numerical
format, or a specific sensor can be queried to return either the sensor status or sensor
value.
Run the command by entering one of the following:
/usr/lpp/diagnostics/bin/uesensor -l | -a /usr/lpp/diagnostics/bin/uesensor -t
token -i index [-v]
Flag
-l
-a
-t token
96
User's Guide
Description
List the sensors and their values in a text format.
List the sensors and their values in a numerical format. For each sensor, the
following numerical values are displayed as: token index status measured
value location code
Specifies the sensor token to query.