Thermostat - FireplaceXtrordinair 2000 36 DV XL Owner's Manual

Built-in direct vent fireplace
Table of Contents

Advertisement

Optional Equipment
5 2
Thermostat (Part # 99300650)
!
Do not connect 120 VAC to the gas control valve or wiring of this unit.
1
Attach the thermostat wire to the on/off switch and route it through the grommet located on either side
of the fireplace (see the illustration below). Pull through all the slack.
Remove the jumper wire on
the back of the on/off switch
and discard.
Red & brown wires
leading to the gas
control valve.
Jumper Wire
(green wire)
2
Determine a location for the thermostat that is within range of the 50' length of thermostat wire. It
should be centralized in the room and away from the fireplace. The wire may be routed externally on
the wall or behind the wall (preferred).
3
Cut the thermostat wire so there is approximately 6" of slack (NOTE: Do not splice thermostat wires
together–this leads to too much electrical resistance). Follow the directions below to install the

thermostat.

d
Attach the thermostat to
the wall through these
two holes.
e
Re-attach the cover
removed in step "a".
Travis Industries
a
Connect the thermostat wires to back
of the on/off switch (orientation does
not matter).
Back of
on/off switch
50
60
70
80
90
Robertshaw
(for qualified installers only)
b
Route the thermostat wire out the grommet-lined
thermostat hole (located behind the hole for the
gas line on either side).
Gas Line
50 60 70 80 90
9 3 5 0 8 1 1 8
c
Thermostat Wire
Hole (with grommet)
a
Pull the cover off the thermostat
b
Run the thermostat wires
through the wall (cut off excess
wire, leaving 6" of slack).
c
Expose 1/2" of wire and
attach to these two posts.
Standard
Screwdriver
2 7 0 9 0 0

Advertisement

Table of Contents
loading

Table of Contents