Hearth Requirements - FireplaceXtrordinair 2000 36 DV XL Owner's Manual

Built-in direct vent fireplace
Table of Contents

Advertisement

Installation

Hearth Requirements

Min. 3/4"
Max. 15/16"
16" Min.
Travis Industries
36" Min. for arch face
38-1/4" Min. for
rectangular face
Cement Board
Raised
Fireplaces
Fireplace Stand
9 3 5 0 8 1 1 8
(for qualified installers only)
Floor Mounted
Fireplaces
Do not build the hearth
above this ledge.
Tile, Marble, Brick, or other
Non-Combustible
Decorative Trim
(may be combustible)
Make sure to accomodate the floor covering (carpet,
linoleum, flooring, etc.) when determining the height of
the fireplace stand (i.e. the thicker the carpet, the taller
the fireplace stand).
9
When raised a minimum of
3" off of the floor surface,
no hearth is required.
2 7 0 9 0 0