Optional Equipment
4 8
3
Attach the starter ring to the fireplace following the directions below (use the most
convenient side).
4
Install the air duct. Each section, when joined, must be attached with three screws and duct tape
(U.L. 181A-P or equivalent). Secure the duct if it is in an area where it may sag or become
dislodged.
NOTE:
Travis Industries
The air duct has a 0" clearance to combustibles.
(for qualified installers only)
1/4" Nutdriver
Starter Ring
Remove and discard the
cover plate.
Bend the tabs on the bottom of
the starter ring up to lock it in
place.
9 3 5 0 8 1 1 8
Secure all ducting
together with screws.
Then seal the seams
with aluminum duct
tape (U.L. 181A-P or
equivalent).
2 7 0 9 0 0