EPSON Stylus CX3100/3200
5.
Using tweezers or the like, disengage the upper and lower hooks on the Harness
Fastening Plate which retain the Harness Fastening Plate to the Shield Cover for
the Main Board.
Harness Fastening Plate
Figure 4-4. Harness Fastening Plate
6.
Remove the Ferrite Core from the Shield Cover for the Main Board.
Ferrite Core
Figure 4-5. Ferrite Core
7.
Disconnect the four lines of harness of the Scanner Unit from the Main Board.
CCD harness:
CN1
HP detector harness:
CN2
Panel harness:
CN6
Motor harness:
CN7
8.
Remove the Ferrite Cores from the CCD harness and Panel harness.
9.
Remove the two (right and left) screws (CBP-Tite 3x10 F/Ni) securing the Scanner
Unit to the Middle Housing.
Disassembly and Assembly
NOTE: Screw tightening torque: 0.5-0.7 Nm
Figure 4-6. Screws securing the Scanner Unit
10. Remove the Scanner Unit upward.
When removing the Scanner Unit, take care not to damage the
C A U T I O N
harness.
Disassembly Process
CBP-Tite 3x10 F/Ni