INSTALLATION – SOLAR COLLECTORS
LATITUDE OF SOME AUSTRALIAN CITIES
Adelaide
35°S
Alice Springs
24°S
Brisbane
27°S
Broken Hill
31°S
PIPE LENGTHS
The solar hot and solar cold pipes between the solar storage tank and the solar collectors shall:
be of DN15 bendable grade or hard drawn copper tube.
Annealed or soft copper shall not be used.
have a continuous fall from the solar collectors to the solar storage tank of a minimum 5° (1 in 10 grade).
not exceed the maximum recommended lengths as specified in the table.
Maximum recommended total combined pipe length (solar cold + solar hot)
Pipe Size
DN15
For each additional 90° bend, reduce the maximum total pipe length by 0.5 metres.
For each additional metre of pipe length, reduce the number of 90° bends by two.
Note: One 90° elbow is equal to two 90° bends.
Notes:
It is important not to cross connect the solar cold and solar hot pipes to the incorrect connections at the
solar collectors and at the solar storage tank.
The solar cold pipe connects to the bottom of the solar collectors and the solar hot pipe connects to the
top of the solar collectors diagonally opposite to the solar cold pipe connection.
The lowest corner of the solar collector installation, which is where the solar cold pipe connects to the
collector array, should be the corner closest to the solar storage tank. This will maximise the gradient for
the continuous fall of the solar cold pipe, by providing a shorter horizontal run of pipe work for the
vertical fall.
The hot sensor connection is at the top of the solar collector, directly above the solar cold inlet
connection.
Refer to
"Warning: Plumber – Be Aware"
It is essential for these requirements to be followed for the system to operate correctly and efficiently. Solar
pipe work which is oversized, or does not have the correct fall, or is too long can result in the drain back
system not operating effectively.
Cairns
17°S
Canberra
35°S
Darwin
12°S
Geraldton
28°S
and number of 90° bends
1 or 2 Collectors
Pipe Length
90° Bends
40 metres
20
on page 31.
Hobart
42°S
Mildura
34°S
Melbourne
38°S
Perth
32°S
3 Collectors
Pipe Length
30 metres
30
Port Hedland
20°S
Rockhampton
24°S
Sydney
34°S
Townsville
19°S
90° Bends
20