Solahart Streamline Owner's Manual page 12

Indirect closed circuit gas boosted solar water heater
Hide thumbs Also See for Streamline:
Table of Contents

Advertisement

REGULAR CARE
TEMPERATURE PRESSURE RELIEF VALVE
This valve is near the top of the water heater and is essential for its
safe operation. It is possible for the valve to release a little water
through the drain line during each heating period. This occurs as the
water is heated and expands by approximately 1/50 of its volume.
Continuous leakage of water from the valve and its drain line may
indicate a problem with the water heater (refer to
"Temperature
Pressure Relief Valve Running"
on page 18).
Warning: Never block the outlet of this valve or its drain line for
any reason.
Operate the easing lever on the temperature pressure relief valve
once every six months. It is very important you raise and lower
the lever gently.
Warning: Failure to do this may result in the water heater
cylinder failing.
Warning: Exercise care to avoid any splashing of water, as
water discharged from the drain line will be hot. Stand clear of the
drain line‟s point of discharge when operating the valve‟s lever.
water
heater
If water does not flow freely from the drain line when the lever is
lifted, then the water heater must be checked. Phone your nearest
Solahart Dealer to arrange for an inspection.
lift until water
The temperature pressure relief valve should be replaced at
flows from the
drain
intervals not exceeding 5 years, or more frequently in areas where
drain line –
line
there is a high incidence of water deposits (refer to
"Water Supplies"
lower gently
on page 13).
EXPANSION CONTROL VALVE
In many areas, including South Australia, Western Australia and scaling water areas, an expansion control
valve is fitted to the cold water line to the water heater. The expansion control valve may discharge a small
quantity of water from its drain line during the heating period instead of the temperature pressure relief valve
on the water heater.
Operate the easing lever on the expansion control valve once every six months. It is very important you
raise and lower the lever gently. The expansion control valve should be checked for performance or
replaced at intervals not exceeding 5 years, or more frequently in areas where there is a high incidence of
water deposits.
COLLECTOR GLASS
Ensure the glass on your solar collectors is free of dust, salt spray or any other matter, which may reduce the
effectiveness of the solar collectors. If the collector glass becomes dirty, hose down or if the solar collectors
are accessible, wash the collector glass with water and a soft brush when the solar collectors are cool.
Have any trees trimmed which may shade the solar collectors.
Solahart solar collectors have passed the AS/NZS 2712 requirements for resistance to hailstone damage, so
it is not normally necessary to fit a guard to a collector. Stone Guards are available to provide a level of
protection to the collectors against vandalism or accidental damage. Refer to your local Solar Distributor for
details.
GENERAL MAINTENANCE
The jacket of the water heater can be cleaned with a soft cloth and warm mild soapy water. Under no
circumstances should abrasive materials or powders be used.