READY LED: Light off
ATTENTION LED: Flash
Trouble or status
An error occurred in the controller.
n = (*1) Exception Code
aaaaaaaa = Error address
1*:
Exception
code
1-3
Reserved
D-F
4
Address Error Exception
5
Address Error Exception (Store
instruction)
6
Bus Error Exception (Instruction Fetch)
7
Bus Error Exception (Load instruction,
store instruction)
8
System Call Exception
9
Breakpoint Exception
A
Reserved Instruction Exception
B
Co-processor Unusable Exception
C
Arithmetic Overflow Exception
Copyright 1998, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business Partner
Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)
Error
Remedy
- Turn the power off, then on.
- Replace the Main board. BOARD-FFF)
Note: When replacing the Main Board, install
the EEPROM mounted on the replaced Main
board.
see above
see above
see above
see above
see above
see above
see above
see above
see above