Status Commands - Comtech EF Data KPA-020IN Installation And Operation Manual

Ku-band solid-state power amplifier
Hide thumbs Also See for KPA-020IN:
Table of Contents

Advertisement

Ku-Band Solid-State Power Amplifier
Remote Control
6.9.4

Status Commands

Configuration
Configuration Status:
Status
Confirmation:
Maintenance
Maintenance Status:
Status
Confirmation:
<DEV/RCS_'cr'
>DEV/RCS_'cr'
ATT_yy.yy'cr'
AMP_nnn'cr'
TX_nnn'cr'
ONL_nnn'cr'
RED_xx_y'cr'
AFR_nnn'cr'
<DEV/RMS_'cr'
>DEV/RMS_'cr'' lf']
V+28_xx.x'cr'
V+12xx.x'cr'
V-12_xx.x'cr'
V+5_x.x'cr'
V–5_x.x'cr'
V+9_1_xx.x'cr'
V+9_2_xx.x'cr'
TEMP_xx'cr'
FPWR_xx.x'cr'
RPWR_xx.x'cr'' lf']
6-12
Revision 0
MN/KPA.IOM
Where:
Attenuator
Amplifier – On/Off
Transmit – On/Off
Online – On/Off
See Note.
Auto Flt Recoverty – On/Off
Notes:
1.
If Redundancy is Off, xx_y = Off,
else if Redundancy is On the xx
field indicates the KPA
designation, either BU (Backup)
01 or 02.
2.
If xx is either 01 or 02 then the y
field indicates the Auto/Manual
status, either A if Auto or M if
manual.
3.
If xx field is BU, the y field
indicates the pripority KPA,
either 1 if KPA #1 is high priority
or 2 if KPA #2 is high priority.
4.
For 1:1 systems prority is
always #1.
Where:
+28 VDC Supply
+12 VDC Supply
–12 VDC Supply
+5 VDC Supply
–5 VDC Supply
9 VDC Supply #1
9 VDC Supply #2
Temperature
RF Forward Power (dBm)
RF Reflected Power (dBm)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kpa-040Kpa-100Kpa-080

Table of Contents