Command/Response Pairs; Utility Commands - Comtech EF Data KPA-020IN Installation And Operation Manual

Ku-band solid-state power amplifier
Hide thumbs Also See for KPA-020IN:
Table of Contents

Advertisement

Ku-Band Solid-State Power Amplifier
Remote Control
6.9

Command/Response Pairs

6.9.1

Utility Commands

Time
Set Time:
Confirmation:
Retrieve Time:
Confirmation:
Date
Set Date:
Confirmation:
Physical Address
Set Physical Address :
Confirmation:
Retrieve Physican
Address:
Confirmation:
Baud Rate
Set Baud Rate:
Confirmation:
Retrieve Baud Rate:
Confirmation:
Parity Bit
Set Parity Bit:
Confirmation:
Retrieve Parity Bit:
Confirmation:
LCD Contrast
Set Contrast:
Confirmation:
Retrieve Contrast:
Confirmation:
LCD Brightness
Set Brightness:
Confirmation:
Retrieve Brightness:
Confirmation:
Lamp Test
Test Lamps:
Confirmation:
KPA-020IN
Lamp Test Status:
Confirmation:
Equipment Type
Retrieve Equipment Type:
Confirmation:
<DEV/TIM_hh:mm:ss'cr'
>DEV/TIM_hh:mm:ss 'cr'' lf']
<DEV/TIM_'cr'
>DEV/TIM_hh:mm:ss 'cr'' lf']
<DEV/DAT_mm/dd/yy'cr'
>DEV/DAT_mm/dd/yy/'cr'' lf']
<DEV/SPA_xxx'cr'
>DEV/SPA_xxx'cr'' lf']
<DEV/SPA_'cr'
>DEV/SPA_xxx'cr'' lf']
<DEV/SBR_xxxx'cr'
>DEV/SBR_xxxx'cr'' lf']
<DEV/SBR_xxxx'cr'
>DEV/SBR_xxxx'cr'' lf']
<DEV/SPB_xxxx'cr'
>DEV/SPB_xxxx'cr'' lf']
DEV/SPB_'cr'
DEV/SPB_xxxx'cr'' lf']
<DEV/CON_xx'cr'
>DEV/CON_xx'cr'' lf']
<DEV/CON_'cr'
>DEV/CON_xx'cr'' lf']
<DEV/LCD_xx'cr'
>DEV/LCD_xx'cr'' lf']
<DEV/LCD_'cr'
>DEV/LCD_xx'cr'' lf']
<DEV/LAM_xxx'cr'
>DEV/LAM_xxx'cr'' lf']
<DEV/LAM_'cr'
>DEV/LAM_xxx'cr'' lf']
<DEV/RET_'cr'
>DEV/RET_xxxxxxx yyyyy'cr'' lf']
6-9
Revision 0
MN/KPA.IOM
Where:
hh = Hour
mm = Minutes
ss = Seconds
Note: 24-hour military is used.
Where:
mm = Month
dd = Day
yy = Year
Where: xxx = 1 to 255
The default physical address is 1.
Where: xxxx = 300, 1200, 2400,
4800, or 9600
The default baud rate is 9600.
Where: xxxx = Odd or Even
The default parity is Even.
Where: xx = 0 to 30
The default is contrast 15.
Where xx = 0 to 30
The default is contrast 15.
Where: xxx = On or Off
Where: xxxxxxx = Model No.
yyyyy = Software Version
Example: >DEV/RET_K080-4045-I SW_1.02
Equipment Type is a command that retrieves
the model number and software version of the
equipment. The information cannot be
changeds by command.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kpa-040Kpa-100Kpa-080

Table of Contents