Error Processing

The following Error Responses may be generated by any command instead of a
confirmation.
General Error
Message:
6.9.7

Configuration Errors

The following Error Responses may be generated by configuration commands.
Configuration Error
Message:
6.9.8

Time-Outs

A time-out should be assumed if there is no response in 1.0 seconds. The station monitor
and control computer should try at least three times. Possible sources of time-outs are
listed in Table 6-2:
>DEV?COM CU COMMAND UNRECOGNIZED'cr'' lf']
>DEV?COM IP INVALID PARAMETER'cr'' lf']
>DEV?COM PE PARITY ERROR'cr'' lf']
>DEV?COM LO DEVICE IN LOCAL MODE'cr'' lf']

Table 6-2. Possible Time-Out Sources

Incorrect Device Address
Faulty Cable
Faulty Connector
I/O fault on remote interface
I/O fault on monitor and control computer
6-20
Revision 0
MN/KPA.IOM