10 Slide the carriage to the right, and
remove it with the belt from the plotter.
Reassembling: Position the belt under the
back extrusion of the carriage.
Make sure that you correctly reconnect the
trailing cable ' page 6 35.
After reassembling, make sure that you check
the carriage to media distance ' page 7 11.
Calibration: After having reassembled the
plotter, perform the black cartridge alignment.
(Details ' User's Guide.)
C4699 90000
Removing the Drive Belt
1 Remove the cartridge carriage ' page 6 37.
2 Release the belt from the clips on the
underside of the carriage.
Reassembling: Clip the belt to the carriage,
using the same part of the belt as was
originally used. Also, match the vertical lines
on the belt with the vertical grooves on the
carriage. The horizontal lines on the belt face
outwards.
Removal and Replacement