BSMI (Taiwan Area)
This product is fully compliant to CNS 13438 (CISPR 22: 1993) Class A. The EMC label is in the form shown
in Figure 4.
Figure 4
Taiwan Area EMC
Electrical practices and suggestions in this guide are based on North American practices. For
NOTE
countries outside North America, local electrical codes will take precedence over North
American electrical codes.
An example would be the recommendation that the PE (protective earthing) conductor be green
with yellow stripes. This requirement is a North American directive and does not override the
local code requirements for a country outside North America.
Throughout this manual, the [LAHJ] acronym will be used to indicate Local Authority Has Jurisdiction.
Acoustics (Germany)
Acoustic Noise (A-weighted Sound Pressure Level LpA) measured at the bystander position, normal
operation, to ISO 7779: LpA = 59 dB.
Geräuschemission (Deutschland)
Lärmangabe (Schalldruckpegel LpA) gemessen am fiktiven Arbeitsplatz bei normalem Betrieb nach
DIN 45635, Teil 19: LpA = 59 dB.
IT Power System
This product has not been evaluated for connection to an IT power system (an AC distribution system having
no direct connection to earth according to IEC 60950).
TT, TN-C, and TN-C-S Power Systems
These products should not be connected to power systems that switch open the return lead when the return
lead also functions as the protective earth (PE). A separate PE ground wire must be connected to the
equipment at the designated PE terminal tie point.