Chapter 3: Mount the Device
You can mount the in a rack.
The chassis fits in most standard 19-inch racks. It is 2U (3.5", 88 mm) high.
Before you Install the in a Rack
Disconnect all cables from the unit before proceeding with the rack installation.
●
When installing in a rack, ensure that the equipment is positioned such that it will not
●
cause the rack to become unstable or tip over.
Ensure that the combination of equipment in the rack will not cause an overload or
●
overcurrent condition on the power strip being used and/or the customer's branch circuit.
The units weigh a maximum of 15 pounds (6.8 kg). Be careful when installing or removing
●
the product from the rack.
If a power strip is being used in the rack, ensure that it has a reliable earth connection. If
●
the equipment will be plugged directly into a wall outlet, ensure that there is a reliable
ground connection at the outlet.
Ensure that the internal rack ambient temperature is within the operating specification
●
limits of the .
Ventilation for the is from side to side. Ensure that there is adequate space on each side
●
of the P330 equipment when installed in the rack to allow sufficient airflow.
Place the in the rack as follows:
Note:
The is used to illustrate this procedure which is the same for all P330-ML
Note:
switches.
1. Snap open the hinged ends of the unit's front panel to reveal the screw holes. Refer to
Figure 2
Figure 2: Closed hinged end
1
Figure notes:
1. Closed hinged end
and
Figure
3.
P332G-ML
1
2
3
4
5
LNK
COL Tx
Rx
FDX
FC
Hspd
LAG
LAG
1
2
3
6
7
8
9
10
11
12
Rout
SYS
OPR
PWR
LAG
4
5
6
7
8
CONSOLE
LAG
9
10
11
12
Issue 1 September 2005
17