To install the VIP module, perform the following steps:
Step
Action
1
Mount the module in the control cabinet if
space is available or, if this is not possible, on
the side of the cabinet or adjacent to it.
If you mount the VIP Module inside the
control cabinet, attach it to the cabinet's
interior surface with 2-faced adhesive tape.
You may leave the module's cover off if it is
mounted within the cabinet.
If you mount the module outside the
cabinet, use the screw holes at the rear to
mount horizontally or vertically (2-faced
adhesive tape may be used, if preferred).
2
Affix the 4285/4286 connections label
(supplied separately) to the inside of the VIP
Module's cover, if the cover is used.
Otherwise, affix the label to the inside of the
control cabinet's door.
3
Make 12V (+) and (–) and data-in and data-
out connections from the VIP Module to the
control, using the connector cable supplied
with the VIP Module. These are the same
connections as for remote keypads.
SPEAKER NOTE: IF CONNECTING SINGLE SPEAKER, USE 8-ohm SPEAKER ONLY.
4286 VIP MODULE
NOTE:
4286 DEVICE
ADDRESS IS
FACTORY SET
TO "4"
YELLOW
GREEN
4500
THERMOSTAT
IMPORTANT NOTE FOR EXISTING INSTALLATIONS:
EXISTING WIRES CONNECTED TO THE "HANDSET"
TERMINALS ON CONTROL MUST BE MOVED FROM
THERE TO TERMINALS 3 AND 4 ON THE 4286.
IF CONNECTING 2 SPEAKERS, USE 4-ohm or 8-ohm SPEAKERS
AND CONNECT IN SERIES.
SPEAKER
VOLUME
CONTROL
NO
CONNECTION
KEYED
HEADER
TO CONTROL PANEL
KEYPAD CONNECTIONS
YELLOW
NO CONNECTION
RED
BLACK
GREEN
U.S. PATENT No. 4791658

Figure 3-27: VIP Module Connections

Section 3 - Installing the Control
Step
Action
4
Connect the module to the phone line as
shown below. See Figure 3-27.
4285/4286 Terminal
1. Phone In (Tip)
2. Phone In (Ring)
3. Phone Out (Tip)
4. Phone Out (Ring)
5. No Connection
6. Audio Out 1∗
7. Audio Out 1∗
Supported by the 4286 only
Use an RJ31X Jack with the phone cable
supplied with the control to make connections
to the VIP module. Make connections exactly
as shown in Figure 3-27. This is essential,
even if the system is not connected to a
central station. The 4285/4286 will not
function if this is not done.
• If touch-tones are not present following phone
access to the security system via an on-
premises phone, try reversing the pair of
wires connected to terminals 3 and 4 on the
4285/4286.
• If the phone plug is disconnected from the
control, the premise's phones will not operate.
SEE SPEAKER NOTE
GREY
BROWN
CALLER ID
EARTH
GROUND
TIP RING TIP RING
HANDSET INCOMING
TELCO LINE
THIS DEVICE COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION No. AC3USA-74659-KX-N
RINGER EQUIVALENCE: 1.0B
FOR COMPLETE INFORMATION, SEE INSTALLATION
INSTRUCTIONS N6431-3 ACCOMPANYING 4286 VIP
MODULE
Connects to direct
connect cord:
green wire
red wire
brown wire
gray wire
Speaker
Speaker
INCOMING TELCO LINE
TIP
RJ31X
RING
PREMISES
JACK
ANSWERING
MACHINE AND
PHONES
UNIT
ANSWERING
MACHINE
4286_wiring-002-V1