FIELD
TITLE and DATA ENTRIES
Daylight Saving Time Start/End
2*02
Weekend
0 = disable
1 = enable

Number of Codes per Partition

2*17
Enter 01-69

Enable GOTO for this Partition

2*18
(partition-specific)
0 = disable
1 = enable

Use Partition Descriptor

2*19
0 = disable
1 = enable

Enable J7 Triggers for Partition

2*20
(partition-specific)
0 = disable
1 = enable

Supervision Pulses for LRR

2*21
0 = disable
1 = enable
5-12
EXPLANATION
Enter the start and end weekends for daylight saving time as follows:
1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from
last. Standard setting for U.S. is 1,5.
This field has two 2-digit entries. Enter the number user codes for each
partition. The total number of user codes cannot exceed 70 for the system.
Enter 01 for an unused partition.
NOTE: The installer code is automatically assigned to each partition
regardless of whether that partition has been enabled.
If enabled, this partition can be accessed from another partition's keypad
using the GOTO command.
If enabled, the normal keypad display will include a partition number and
four-digit descriptor.
If enabled, the J7 triggers function for this partition.
There are three entries in this field as follows: Fire, Burglary/Audible
Panic, Silent Panic/Duress.
If enabled, causes the control to send periodic short pulses on the J7 radio
triggers to the LRR. The LRR uses these pulses to determine that its
connection to the control is still intact.
Must be 1 for UL installations.