Phone Line/Phone Module, and Audio Alarm Verification (AAV) Connections

Phone Line

4285/4286 Phone Module

Compatibility: 4286 Phone
Modules must have
software version WA4286-
15.1 or higher (refer to the
label on the square 4286
microprocessor chip).
U L
The 4285 and 4286
modules are UL Listed only
for use on residential fire
and UL residential burglar
alarm installations.

Phone Module Problems

Connect incoming phone line and handset wiring to the main terminal block (via an
RJ31X jack) as shown in the Summary of Connections diagram at the back of this
manual.
Wire colors represent the colors of the cable to the RJ31X jack.
1. Make 12V (+) and (–) and data in and data out connections from the phone module to
the control, using the connector cable supplied with the phone module, then insert
the keyed connector at the other end of the connector cable into the header on the
phone module.
2. Connect Phone Module terminals as shown below. Use an RJ31X jack with a direct-
connect cord and make all connections exactly as shown.
3. Caller ID Units: If a Caller ID unit is being used, connect the unit directly to the
"Handset" terminals (21 & 22) on the control, as shown.
TERMINALS
ON CONTROL
CALLER ID
UNIT
IMPORTANT NOTE FOR
EXISTING INSTALLATIONS:
EXISTING WIRES
CONNECTED TO THE
"HANDSET" TERMINALS ON
CONTROL MUST BE MOVED
FROM THERE TO TERMINALS
3 AND 4 ON THE 4285/4286.
4285/4286
V IP MODULE
LOUDER
VOLUME
(4286
KEYED
ONLY)
HEADER
UNUSED
YELLOW: TO DATA OUT (term. 7)
NO CONNECTION
RED:
TO AUX (+) (term. 5)
CONNECTOR
BLACK:
TO AUX. GROUND (–) (term.4)
WITH FLYING
GREEN: TO DATA IN (term. 6)
LEADS
Figure 16. 4285/4286 Phone Module Wiring Connections
• Only one phone module can be used and it can only be connected to partition 1.
• The phone lines must be in service for the phone module to function, even when
accessing the system from an on-premises phone.
• If you are also using an Audio Alarm Verification (AAV) unit, refer to Audio Alarm
Verification (AAV) section for special wiring connections.
CAUTION: To reduce the risk of fire, use only No. 26 AWG or larger telecommunication
line cord for phone line connections.
If no touch tones are produced following access to the security system from on-premises
(this problem may arise in rare cases), it may be necessary to reverse the wires connected
to terminals 3 and 4 on the phone module and the wires connected to terminals (21) &
(22) on the control. The wiring diagram shows the wiring connections that will provide
proper operation in most cases.
Connection to the incoming telco line via a RJ31X jack and direct-connect cord, as shown,
is essential, even if the system is not connected to a central station. The 4285 or 4286 will
not function if this is not done and an error signal (fast busy signal) will occur when
trying to access the system via the phone.
The house phone lines (gray and brown wires) must be wired to the phone module
terminals; not to the control terminals. Otherwise, an error signal (fast busy signal) will
occur when trying to access the system from an on-premises phone.
Mounting and Wiring the Control
INCOMING
GROUND
HANDSET
TELCO LINE
21
22
23
24
25
TO EARTH GROUND (COLD WATER PIPE, ETC.)
DIRECT
CONNECT
CORD
RJ31X
JACK
CA38A
IN
PLUG
CANADA
* NOTE: IF THE TELEPHONE HAS BUILT-IN CALLER ID,
THE CALLER ID FUNCTION MAY NOT WORK .
TO CONTROL
PANEL
TERMINALS
USED FOR
KEYPAD
CONNECTIONS
INCOMING TELCO LINE
TIP
RING
PREMISES ANSWERING
MACHINE AND PHONES
ANSWERING
MACHINE
*
*
4285/4286
TERMINAL ASSIGNMENTS
1 - TIP
}
PHONE INPUT
2 - RING
3 - TIP
}
PHONE OUTPUT
4 - RING
5 - NO CONNECTION
6 -
}
AUDIO OUT
7 -
4286 ONLY
2-13