Clearance to Combustibles
Back
Side
Floor
Top Stand-off
Top Framing Edge 3" (76 mm)
SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH
SEE MANTLE CHAR
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
FINISHED WALL
(COMBUSTIBLE)
TOP FRAMING
LEDGE
GLASS FRONT
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
Note: When using Empire EMBF, UMC, and UMF Series Full Man-
tels, combustible clearance may be reduced to 1" clearance from
top edge of fireplace face.
FRONT FACE (SIDE)
Page 18

CLEARANCES

0" (0 mm)
0" (0 mm)
0" (0 mm)
0" (0 mm)
2" x 4" HEADER
STAND OFF
STAND OFF
3" (76 mm) HEIGHT
ABOVE TOP
ABOVE TOP OF
FIREPLACE
FIREPLACE
NAILING
NAILING
FLANGES
FLANGES
Figure 27
COMBUSTIBLE
MATERIALS ALLOWED
IN SHADED AREAS
3
MAX.
45°
FIREPLACE
(TOP VIEW)
6
PERPENDICULAR
SIDE WALL
Figure 28
Mantel Chart
DISTANCE FROM TOP
INDEX
EDGE OF FIREPLACE
LETTER
(HORIZONTAL)
A
15" (381mm)
B
15" (381mm)
C
13-3/4" (349mm)
D
11" (279mm)
E
8" (203mm)
F
6" (152mm)
G
3" (76mm)
Clearances
This fireplace is not been tested nor approved to have a television
or other electrical appliance installed above it.
Clearance from top front edge of fireplace to ceiling is 36"
Clearance from side of fireplace to adjacent sidewall is 6".
DISTANCE FROM
FIREPLACE FRONT
(VERTICAL)
12" (305mm)
10" (254mm)
8" (203mm)
6" (152mm)
3-3/4" (95mm)
2-1/4" (57mm)
0" (0mm)
Figure 29
WARNING
Figure 30
32261-5-0414