FBB10 BLOWER KIT INSTALLATION (OPTIONAL)
9.
Install blower through firebox cutout. See Figure 12.
10. Install the blower onto the prebent brackets on the blower
plate. Ensure the Velcro connects to secure the blower in
place. See Figure 13.
11. Reinstall the latch assembly removed in step 8. See Figure
11.
12. Reinstall the burner assembly and seven screws removed in
step 7. See Figure 10.
13. Reinstall the burner and four screws removed in step 6. See
Figure 9.
14. Reinstall the log support and secure it with the metal plate and
two screws removed in step 5. See Figure 8.
15. Reinstall the grate three screws removed in step 4. See Fig-
ure 7.
16. Install thermo disc by snapping into valve bracket burner as-
sembly. See Figure 14.
32261-5-0414
Figure 12
Figure 13
17. Connect Power source into outlet.
18. Reinstall the glass frame removed in step 3. See Figure 6.
19. Reconnect the latches at the bottom of the firebox assembly.
See Figure 5.
20. Replace bottom assembly removed in step 1. See Figure 4.
1
3
BLOWER ASSEMBLY PARTS LIST
INDEX
PART
NO.
NO
1
R2804
2
R7649
FAN, CONTROL L120-20
3
R3529
4
R4192
5
R4186
RHEOSTAT, 3.0 AMP 115 VAC
6
10088
RHEOSTAT BOX BRACKET
7
R11768
WIRE HARNESS, FAN CONTROL
Figure 14
5
4
DESCRIPTION
BLOWER ASSEMBLY
CORD SET, 30 INCHES
RHEOSTAT, KNOB
2
7
6
QTY
1
1
1
1
1
1
1