CLEARANCE TO COMBUSTIBLES
Back
Side
Floor
Top Framing Edge
SEE MANTLE CHART FOR
MAXIMUM MANTEL DEPTH
FINISHED WALL
(COMBUSTIBLE)
SEE MANTEL CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
FINISHED WALL
(NON-COMBUSTIBLE)
(NON-COMBUSTIBLE)
BOARD
SCREW HEAD
GLASS FRONT
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
FRONT FACE (SIDE)
FIREPLACE
(TOP VIEW)
Page 14

CLEARANCES

(Inches)
0
0
0
See Below
2" x 4" HEADER
9"
Figure 19
COMBUSTIBLE
MATERIALS ALLOWED
IN SHADED AREAS
3
MAX.
45°
6
PERPENDICULAR
SIDE WALL
Figure 20
Mantel Chart
24"
MINIMUM TO
CHASE TOP
INDEX
LETTER
A
B
C
D
E
F
G
Clearances
Clearance from bottom edge of fireplace to ceiling is 72-inches.
Clearance from side of fireplace to adjacent sidewall is 6-inches.
Refer to framing dimensions on page 22.
NOTICE: 72 inch minimum applies when unit is installed in wall
above floor level.
G
F
E
D
C
B
FIREPLACE OPENING
DISTANCE FROM TOP
EDGE OF FIREPLACE
(VERTICAL)
(Inches)
18
6
9
11
14
16-3/4
18
Figure 21
Figure 22
DISTANCE FROM
FIREPLACE FRONT
(HORIZONTAL)
12
0
2-1/4
3-3/4
6
8
10
37606-4-0718