Combustible Surround Installation
2 X 4
HEADER
STAND OFF
Attention: Cold climate installation recommendation: When
installing this unit against a non-insulated exterior wall, it is
recommended that the outer walls be insulated to conform to
applicable insulation codes.
32261-5-0414
INSTALLATION (continued)
MANTELSHELF
COMBUSTIBLE SURROUND
FINISHED WALL
FRONT TRIM OR NON-COMBUSTIBLE
MATERIAL (INSTALLATION IS OPTIONAL)
JOINT BETWEEN FINISHED WALL AND
UNIT SEALED WITH 300° F 149
° C
SEALANT
MATERIAL (SEALANT IS OPTIONAL)
Figure 42
Vent Runs
In planning the installation for the fireplace, it is necessary to install
certain components before the appliance is completely positioned
and installed. These include the direct vent system, gas piping for
the appliance and the electrical wiring. (If the fan option is used.)
The appliance can be mounted on any of the following surfaces:
1.
A flat, hard combustible (burnable) surface.
2.
A raised wooden platform.
3.
Four corner supports. (Example: Four concrete masonry blocks.)
These supports must be positioned so they contact all four
perimeter edges on the bottom of the unit.
VERTICAL, 90 DEGREE ELBOW WITH HORIZONTAL
TERMINATION
"A"
DISTANCE
TO BOTTOM
OF UNIT
"A" DIMENSION
DVCP32
DVCP36
DVCP42
3" (76mm)
MINIMUM CLEARANCE
TO COMBUSTIBLES
12" Rise
Required
VENT CAP/
THIMBLE
WALL FIRESTOP
57-1/2" (146 cm)
57-1/2" (146 cm)
59-1/8" (151 cm)
Figure 43
Page 23