JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS

CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL,
CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY
IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL
CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION).
A factory installed junction box is located on the lower right side of
the fireplace. Wiring must be fed to the junction box and attached
to the receptacle that is provided. Leave approximately 6" of wire
in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to
opposite side of receptacle. The ground wire should be attached
to the green (ground) screw.
Install the receptacle into the junction box. Attach cover plate.
BLACK
TO 120V
WHITE
CIRCUIT
BREAKER
GROUND
1.
Power for switched and live sides of receptacle must come from
the same power source. (One circuit breaker on main panel
must switch all power off.)
2.
From the wall box to the fireplace a 3-wire conductor with
ground is recommended, however 2 two-wire conductors with
grounds may be used in place of a 3-wire conductor with a
ground if the black wires from the thermostat and blower switch
are identified.
3.
Two wall switches, or a wall switch and thermostat may be
used to activate the receptacle plugs independently.
Page 54
MILLIVOLT VALVE MODELS
IP VALVE MODELS
DOUBLE SWITCH BOX
(INSTALLER PROVIDED)
DUAL SWITCH ELECTRICAL WIRING TO FIREPLACE RECEPTACLE
BLACK
WHITE
FIREPLACE
CONTROL
COMPARTMENT
3 WIRE, GROUNDED
CONDUCTOR
(BY OTHERS)