Increasing the Lamp's
Legend™ 230SR Beam User Manual Rev. 1
4. Remove the 2 Phillips head screws on the sides of the fan assembly.
5. Roll the fan assembly to the right to expose the lamp.
6. Using the lamp base, push the lamp down against the spring clips located on the
bottom, then roll the lamp out the top.
7. Remove the 2 wires connected to the lamp by spade connectors.
8. Reverse the steps above to install the new lamp.
• ALWAYS turn the lamp off by using the DMX controller or the product's control
panel. Then wait at least 5 minutes before switching off the product. This will
Life
keep the fans running to extract any remaining heat from the product's head.
• DO NOT power cycle the product unless it is necessary.
• DO NOT touch the lamp without wearing gloves to avoid leaving grease on the
bulb or on the contacts that could reduce the lamp's life.
• ALWAYS change the lamp when it has reached its recommended lifespan to
avoid the risk of lamp explosion.