Technical Specifications
Power
AC 120V 60Hz
Fuse
20mm Glass 10A Fast Blow
Lamps
Dimension
560mm x 250mm x 205mm / 22in x 9.8in x 8.1in
Weight
17 kg / 37.4 lbs
User Information (Please complete for your records)
Data Purchased :
/
/
Dealer Stamp :
Model : TRACKSCAN DMX-606R
AC 230~250V 50/60Hz
20mm Glass 10A Fast Blow
MSD 250W (2000hrs)
13.5 kg / 29.7 lbs
Serial No. :
TRACKSCAN 250R
DMX-606R
User Guide
Please read these instructions carefully before use
World-wide Headquarters:
th
3000 North 29
Ct., Hollywood, Florida, USA, FL 33020
Tel: +1-954-929-1115 Fax: +1-954-929-5560
www.ChauvetLighting.com

Advertisement

loading

Summary of Contents for Chauvet TRACKSCAN 250R

  • Page 1 560mm x 250mm x 205mm / 22in x 9.8in x 8.1in Weight 17 kg / 37.4 lbs 13.5 kg / 29.7 lbs TRACKSCAN 250R DMX-606R User Guide Please read these instructions carefully before use User Information (Please complete for your records) Data Purchased : Serial No.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. Safety Instruction 2. Technical Specification 2.1 Inserting / Exchanging rotating gobos 3. Lamp 3.1 How to change the frequency 50Hz / 60Hz 4. How To Set The Unit 4.1 Control Panel 4.2 Main Function 5. How To Control The Unit 5.1 Master/Slave Built-In Preprogrammed Function.
  • Page 3: Safety Instruction

    The unit is for indoor use only. Use only in a dry location. The unit must be installed in a location with adequate ventilation, at least 50cm from EC Declaration of Conformity adjacent surfaces. Be sure that no ventilation slots are blocked. Disconnect main power before fuse/lamp replacement or servicing.
  • Page 4 E. One of the channels is not working well 1. The stepper motor might be damaged or the cable connected to the PCB is broken. 2. The motor’s drive IC on the PCB might be out of condition. F. The lamp is cutting out intermittently 1.
  • Page 5: Technical Specification

    3 pin XLR connectors are more popular than 5 pin XLR. 3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 2.
  • Page 6: Lamp

    White-Blue 07-13 Stopped White 00-09 00-12 Blackout White 00-07 00-06 Shaking 5.2 Easy Controller 168~247 The easy remote control is used only in master/slave mode. By connecting to the 1/4” microphone jack of the first unit, you will find that the remote control on the first unit will Slowest speed control all the other units for Stand by, Strobe/Next and Fast/Slow function.
  • Page 7: How To Change The Frequency 50Hz / 60Hz

    DMX input present Lamp : Discharge lamp MSD 250W MASTER master mode Color Temperature : 8000K SLAVE slave mode Average Life : 2000 hours SOUND Flashing sound activation 1. Always switch off the main supply and never handle the lamp or luminaries when is Button hot.
  • Page 8 DMX512 Address Setting Show Mode " Show 1 " Show Mode " Show 2 " Slave Mode " Normal " Slave mode " 2 Light Show 2 " Self-Test Normal Color Press the MENU button up to when the is blinking on the display. Pressing Split Color ENTER button and the unit will run self-test by built in program.
  • Page 9 button to setup or automatically return to the main functions without any change after 8 Display normal mode for the fixture putting on the floor. seconds. To go back to the functions without any change press the MENU button again. Display inversion mode for the fixture fixing under ceiling.