D. Vent Diagrams
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling fi restops.
• ALWAYS maintain specifi ed clearances around venting and fi restop systems.
• Install wall shield and ceiling fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe may cause fi re.
1. Top Vent - Horizontal Termination
One Elbow
Note: Must have a 12 inches
minimum vertical vent before
attaching any elbow to the unit.
Figure 5.3
Two Elbows
H
2
Figure 5.4
H
1
Note: Must have a 12 inches
minimum vertical vent before
attaching any elbow to the unit.
INSTALLED
HORIZONTALLY
Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08
WARNING
V
1
V
H
1
V
Minimum
H
1
1 ft.
305 mm
1-1/2 ft.
1-1/2 ft.
457 mm
2 ft.
2 ft.
610 mm
5 ft.
3 ft.
914 mm
8 ft.
4 ft.
1219 mm
11 ft.
5 ft.
1524 mm
14 ft.
6 ft.
1829 mm
17 ft.
7 ft.
2134 mm
20 ft.
8 ft.
2438 mm
23 ft.
V
+ H
= 63 ft. (19.2 m) Maximum
1
1
V
Minimum
H
+ H
1
1
1 ft.
305 mm
2 ft.
1-1/2 ft.
457 mm
2-1/2 ft.
2 ft.
610 mm
5-1/2 ft.
3 ft.
914 mm
8-1/2 ft.
4 ft.
1219 mm
11-1/2 ft.
V
+ H
+ H
= 63 ft. (19.2 m) Maximum
1
1
2
H
+ H
= 23 ft. (7.1 m) Maximum
1
2
1
Maximum
1
457 mm
610 mm
1524
2438
3353
4267
5182
6096
7010
Maximum
2
610 mm
762 mm
1676 mm
2591 mm
3505 mm