Vent Diagrams - Heat & Glo SLF-550TR-IPI-E Owner's Manual

Table of Contents

Advertisement

F. Vent Diagrams
Top Vent - Horizontal Termination
Venting with one 90º elbow
V
Minimum
1
90 Elbow *
1/2 ft.*
1-1/2 ft.* 457 mm
2-1/2 ft.* 762 mm
3-1/2 ft.
4-1/2 ft.
H MAX. =14 ft. (4.3 m)
V + H MAX. = 40 ft. (12.2 m)
Fire Risk.
• When using SLP-HRC-SS and SLP-HRC-ZC-SS
termination caps on top vented fi replaces, a one
foot minimum vertical vent section is required before
installing fi rst elbow.
• When using DVP-TB1 termination cap on top vented fi replaces,
a three foot minimum vertical vent section is required before
installing fi rst elbow.
Figure 7.4
24
H
Maximum
1
SLF-550TR-IPI-E
2 ft.
610 mm
152 mm
2 ft.
610 mm
3 ft.
914 mm
5 ft.
1.5 m
1.1 m
7 ft.
2.1 m
1.4 m
14 ft.
4.3 m
* See warning below
WARNING *
Heat & Glo • SLF-550TR-IPI-E • 2118-901 Rev. B • 7/12
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 7.3).
H
1
V
1