Heat & Glo Escape-36DV Owner's Manual page 15

Hide thumbs Also See for Escape-36DV:
Table of Contents

Advertisement

2. Top Vent - Vertical Termination
No Elbow
Figure 5.6
Flue Restrictor Instructions
1. The fl ue restrictor (Figure 5.7) is located behind the right
side panel. Use the restrictor if the vertical vent run is
over 20 feet and has NO elbows.
FLUE
RESTRICTOR
Figure 5.7
V
1
FLUE RESTRICTOR
Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08
Note: On vertical venting confi gura-
tions install the fl ue restrictor (located
behind the right side panel) per the
following fl ue restrictor instructions.
2. The restrictor sits inside the 5" diameter collar in the
bead area. Using a needle-nose pliers, insert the tips
of the pliers into the two holes in the restrictor plate.
Squeeze the pliers to fl ex the plate. The edges of the
plate will need to overlap each other. Insert the plate into
the 5" collar from inside the fi rebox. Release the pliers,
the plate will expand into the bead (groove) inside the
collar. Make sure the plate is fully in the groove so the
restrictor cannot fall out (see Figure 5.8).
3"
DIAMETER
Figure 5.8 Flue Restrictor
V
= 40 ft. Max. (12.2 m)
1
15