CRS-170A L-Band 1:1 Redundancy Switch
Introduction
Note the following: 
 
1. The  Managed  Switch  Mode  method  of  redundancy  is  intended  to  be  equivalent  to  pulling 
the Ethernet cable from one port and putting it into a different port on the same switch. 
 
2. For  the  CDM‐625  modem:  The  user  may  configure  one  of  the  CDM‐625's  four  available 
10/100  Ethernet  ports  for  M&C  Ethernet.  As  configured  in  Dedicated  Management  Port 
Mode,  when  the  modem  is  offline  the  M&C‐designated  port remains functional  and 
available for operation, while the three remaining ports are unavailable. Otherwise, if none 
of  the  10/100  Ethernet  ports  are  reserved  for  M&C  operation,  all  four  ports become 
unavailable when the modem is offline.  
 
 
Refer  to  the  CDM‐625  Advanced  Satellite  Modem  Installation  and  Operation  Manual  for 
instructions to configure one of the four 10/100 Ethernet ports for each modem for remote 
Ethernet M&C.   
 
 
3. For  the  CDM‐750/700/710/710G  modems:  When  the  modem  is  offline,  although all 
GigE port(s) are  unavailable,  the  M&C  Ethernet  port  remains  functional  and  available  for 
operation.   
 
4. Installation must use a true switching device, not a hub device. 
1.2.1.1.3
CDM-625 (with Optional IP Packet Processor) – Router Mode
All  configuration  changes  can  only  be  made  to  the  Online  Modem  and  will  require 
the  User  to  "Save  Parameters  to  permanent  storage"  to  ensure  the  configuration 
change is also applied to the Backup Modem. 
 
For  the  CDM‐625  with  the  optional  IP  Packet  Processor  installed  and  enabled  and  the 
configuration set for Router Mode, the user needs to provide an external Ethernet switch. 
 
In Router Mode, both modems must be assigned a unique Management IP address on the same 
subnet  (172.18.10.21/24  and  172.18.10.22/24  as  shown  in  Figure  1‐8  and  Figure  1‐9).  This  is 
used  to  share  the  param  file.  A  Traffic  IP  address  on  the  subnet  must  also  be  assigned 
(172.18.10.20/24) in the online modem. 
The Traffic IP Address must be different from either Management IP Address. 
This configuration must be enabled on both modems. 
Dedicated  Management  Port  Mode  is  not  configurable  for  use  when  the 
optional  IP  Packet  Processor  is  installed  and  enabled.  With  the  IP  Packet 
Processor enabled, as a means to avoid Ethernet Networking Loops, only one 
of the CDM‐625's four 10/100 Ethernet Ports is used for each modem at any 
given time.
1–12
Revision 9
MN/CRS170A.IOM