1.2.2 Operation With Cdm-600L (Clm-9600L) And Sdm-300L3; Operation With Cdm-600L (Clm-9600L) And Crs-150; Figure 1-9. Cdm-625 1:1 Ip Redundancy Router Mode - Switchover ('B' Online) - Comtech EF Data CRS-170A Installation And Operation Manual

L-band 1:1 redundancy switch
Table of Contents

Advertisement

CRS-170A L-Band 1:1 Redundancy Switch
Introduction
 
 
Figure 1-9. CDM-625 1:1 IP Redundancy Router Mode – Switchover ('B' Online)

1.2.2 Operation with CDM-600L (CLM-9600L) and SDM-300L3

Operation with two CDM‐600L (CLM‐9600L) modems requires an additional CRS‐150 1:1 switch 
for  terrestrial  data  switching  and  1:1  control,  while  operation  with  two  SDM‐300L3  modems 
requires an additional SMS‐301 1:1 switch to handle terrestrial data and control. Thus, there are 
three functional configurations for the CRS‐170A. 
 

1.2.3 Operation with CDM-600L (CLM-9600L) and CRS-150

The  CRS‐150  connects  to  two  modems  (an  online  unit  and  a  standby  unit),  monitors  the  fault 
status of these two units, and controls the routing of data to and from the two units. IF signals, 
10MHz  reference  signals,  DC  power  for  the  BUC  and  LNB,  and  FSK  signaling  to  the  BUC  are 
switched  in  the  CRS‐170A  under  control  of  the  CRS‐150.  In  the  case  of  an  equipment  failure, 
automatic switching takes place to protect the traffic circuit. 
1–14
Revision 9
MN/CRS170A.IOM