Config Mismatch
2.5.2.5
When a "Config Mismatch" occurs in the Switch Status column, it indicates inconsistent entries in the
"Preconfigured Model Identifier" and "Plugged-in Model Identifier" columns. This usually occurs after a
renumbering of units when the stack consists of multiple models, but can also occur after a new unit is
added to the stack when the stack has been preconfigured to expect a different switch model. In the
picture below, these columns show a preconfigured model of N4064 and a plugged-in model of N4032F.
The plugged in model will always be the actual model that is physically a member of the stack. The
preconfigured model must be changed to show the same. To sync the two, the Unit must temporarily be
removed using the "Remove" tool in System > Stack Management > Unit Configuration > Detail tab, then
added back using the "Add" tool in System > Stack Management > Unit Configuration > Add tab.
53