Setting E-mail Settings

Document 800-01794 Rev A
04/08
Table 1-9
Trigger Settings Fields
Field
Description
time lapse
The time (in seconds) between regular periodic trigger events. 0
period
means there are no time lapse trigger events.
image size
Downsample (shrink) the image. Options are:
1 (1280 x 1024), default
1/2 (640 x 512)
1/4 (320 x 256)
1/8 (160 x 128)
For example, selecting 1/4 reduces the image to a fourth its
original width and height. Smaller images are processed and
transmitted more quickly.
forced idletime
The minimum time in seconds between trigger events. Your
(sec)
camera will not trigger another event until the specified amount of
time elapses after the last post-trigger image.
# pre /
The number of images your camera saves from each trigger
-post-trigger
event.
images
Note
pre-/ -post
The time, in seconds, between successive pre- and post- trigger
trigger interval
images.
(sec)
Use the E-mail dialog box to configure e-mail notifications of trigger events.
Note
The domain name and mailserver settings must be properly configured on the
Network Settings page for e-mail to operate properly.
Figure 1-20
E-mail Dialog Box
HCX Series Network IP Camera Operator Guide
Your camera can store only a limited number of trigger
event images. This number depends on the size of your
images. Cropping or downsampling allows storage of
more images. Pre-trigger count plus post-trigger count
should not exceed 8. It is recommended that you test
(click
below the Status bar) to see that you
get the desired number of trigger images.