Smartports

Web GUI

STEP 1
STEP 2
STEP 3
STEP 4
STEP 5
STEP 1
STEP 2
STEP 3
TIP
Web GUI
Cisco 500 Series Stackable Managed Switch Administration Guide
Workflow4:
To rerun a Smartport macro after it has failed, perform the
following steps:
Interface Settings
In the
Click Show Diagnostics to see the problem.
Troubleshoot, then correct the problem. See the troubleshooting tip below.
Click Edit. A new window opens in which you can click Reset to reset the interface.
Return to the main page and reapply the macro using either Reapply (for devices
that are not switches, routers or APs) or Reapply Smartport Macro (for switches,
routers or APs) to run the Smartport Macro on the interface.
A second method of resetting single or multiple unknown interfaces is:
Interface Settings
In the
Unknown
Select
and click Go.
Click Reset All Unknown Smartports. Then reapply the macro as described above.
The reason that the macro failed might be a conflict with a configuration on the
interface made prior to applying the macro (most often encountered with security
and storm-control settings), a wrong port type, a typo or an incorrect command
within the user-defined macro, or an invalid parameter setting. Parameters are
checked for neither type nor boundary prior to the attempt to apply the macro,
therefore, an incorrect or invalid input to a parameter value will almost assuredly
cause failure when applying the macro.
The Smartport feature is configured in the
Type Settings and Interface Settings pages.
For Voice VLAN configuration, see the
For LLDP/CDP configuration, see the
sections, respectively.
page, select an interface with Smartport type Unknown.
Port Type
page, select the
Smartport >
Voice VLAN
Configuring LLDP
equals to checkbox.
Properties,
Smartport
section.
and
Configuring CDP