4
Installing the boiler
4.3

Mounting the adjustable feet (included with B-kit)

Level the boiler with the adjustable feet to prevent air
pockets forming inside the boiler.
Requirement: the burner hood/burner door panel must
have been removed first (
If the boiler is mounted on top of a horizontal
hot water tank, the adjustable feet are not
needed.
V Tilt the boiler with the aid of a hand truck or trolley
(
Chapter 3.3, page 13) or place a wooden batten
underneath it.
V Screw in adjustable feet ¼" – 3/8".
V Gently set the boiler down.
4.4

Positioning and leveling the boiler

V Position the boiler in its final location.
V Level the boiler horizontally by turning the adjustable
feet and using a level.
Protect boiler connections from damage and
dirt if the boiler is not installed immediately.
16
Chapter 3.1, page 12).
Logano G115 WS US/CA - Technical specifications are subject to change without prior notice.
1
2
Fig. 10 Fitting adjustable feet
1
Angle bracket
2
Adjustable feet
Fig. 11 Leveling the boiler horizontally
7 747 019 141-10.1RS
7 747 019 141-11.1RS