U630 Setting Communication Control; Setting The Communication Starting Speed; Setting The Reception Speed - Kyocera KM-1820 Service Manual

Includes: fax system (k)
Hide thumbs Also See for KM-1820:
Table of Contents

Advertisement

Maintenance
item No.
U630
Setting communication control 1
Description
Makes settings for fax transmission regarding the communication.
Start
1. Press the enter key. The screen for selecting an item is displayed.
2. Select the item to be set using the up/down cursor keys.
3. Press the enter key. The screen for the selected item appears.
Display
1:TX SPEED
2:RX SPEED
3:TX ECHO
4:RX ECHO

Setting the communication starting speed

Sets the initial communication speed when starting transmission. When the destination unit has V.34 capability,
V.34 is selected for transmission, regardless of this setting.
1. Change the setting using the up/down cursor keys.
Display
1: 14400bps/V17
2: 9600bps/V29
3: 4800bps/V27ter
4: 2400bps/V27ter
2. Press the enter key. The value is set.
3. To return to the screen for selecting an item, press the back key.

Setting the reception speed

Sets the reception speed that the sender is informed of using the DIS or NSF signal. When the destination unit
has V.34 capability, V.34 is selected, regardless of the setting.
1. Change the setting using the up/down cursor keys.
Display
1: 14400bps
2: 9600bps
3: 4800bps
4: 2400bps
2. Press the enter key. The value is set.
3. To return to the screen for selecting an item, press the back key.
Setting the waiting period to prevent echo problems at the sender
Sets the period before a DCS signal is sent after a DIS signal is received. Used when problems occur due to
echoes at the sender.
1. Change the setting using the up/down cursor keys.
Display
1: 500
2: 300
2. Press the enter key. The value is set.
3. To return to the screen for selecting an item, press the back key.
Description
Description
Sets the communication starting speed.
Sets the reception speed.
Sets the waiting period to prevent echo problems at the sender.
Sets the waiting period to prevent echo problems at the receiver.
Description
V.17, 14400 bps
V.29, 9600 bps
V.27ter, 4800 bps
V.27ter, 2400 bps
Description
V.17, V.33, V.29, V.27ter
V.29, V.27ter
V.27ter
V.27ter (fallback only)
Description
Sends a DCS 500 ms after receiving a DIS.
Sends a DCS 300 ms after receiving a DIS.
3JG