U011Xx Error Code Table: G3 Reception - Kyocera KM-1820 Service Manual

Includes: fax system (k)
Hide thumbs Also See for KM-1820:
Table of Contents

Advertisement

3JG

(2-6) U011XX error code table: G3 reception

Error code
U01100
Function of the unit differs from that indicated by a DCS signal.
U01101
Function of the unit (excl. communication mode select) differs from that indicated by an NSS
signal.
U01102
A DTC (NSC) signal was received when no transmission data was in the unit.
U01110
No response after transmission of a DIS signal.
U01111
No response after transmission of a DTC (NSC) signal.
U01112
No training reception after reception of a DCS or NSS signal.
U01113
No response after transmission of an FTT signal.
U01114
No message reception after transmission of a CFR signal.
U01115
No message reception after transmission of an MCF signal.
U01116
No message reception after transmission of a PPR signal.
U01117
No message reception after transmission of a CTR signal.
U01118
No message reception after transmission of an ERR signal.
U01119
No further signals were received after reception of a message.
U01120
No response after transmission of an MCF signal.
U01121
No response after transmission of an RTP signal.
U01122
No response after transmission of an RTN signal.
U01123
No response after transmission of a PIP signal.
U01124
No response after transmission of a PIN signal.
U01125
No response after transmission of a CNS signal (between units of our make).
U01126
No response after transmission of a PPR signal (ECM).
U01127
No response after transmission of an ERR signal (ECM).
U01128
No response after transmission of an RNR signal (ECM).
U01129
No response after transmission of an SPA signal (short protocol).
U01140
A DCN signal was received after transmission of a DIS signal.
U01141
A DCN signal was received after transmission of a DTC signal.
U01142
A DCN signal was received after transmission of a DCS or NSS signal.
U01143
A DCN signal was received after transmission of an FTT signal.
U01144
A DCN signal was received after transmission of a CFR signal.
U01145
A DCN signal was received after reception of a message.
U01146
A DCN signal was received after transmission of an MCF signal (interoffice communication after
reception of an MPS, EOM signal or confidential interoffice communication).
U01147
A DCN signal was received after transmission of an RTP signal.
U01148
A DCN signal was received after transmission of an RTN signal.
U01149
A DCN signal was received after transmission of a PIP signal.
U01150
A DCN signal was received after transmission of a PIN signal.
U01151
A DCN signal was received after transmission of a PPR signal (ECM).
U01152
A DCN signal was received after transmission of a CTR signal (ECM).
U01153
A DCN signal was received after transmission of an ERR signal (ECM).
U01154
A DCN signal was received after transmission of an RNR signal (ECM).
U01155
A DCN signal was received after transmission of an SPA signal (short protocol).
U01160
During message reception, transmission time exceeded the maximum transmission time per line.
U01161
Number of error lines exceeded limits during message reception.
U01162
A break in loop current was detected during message reception.
U01163
Polarity reversal was detected during message reception.
U01164
One page length exceeded the specified length during message reception.
U01170
A decoding error occurred during MMR message reception.
U01172
During reverse polling in V.34 mode at the transmitting unit, a JM signal was not detected after
transmission of a CM signal when receiving after transmission.