3JG
Maintenance
item No.
U620
Setting the communication system
Description
Sets the signal detection method for remote switching. Be sure to change the setting according to the type of
telephone connected to the machine.
Method
1. Press the enter key. The screen for selecting an item is displayed.
2. Press the enter key.
3. Change the setting using the up/down cursor keys.
Display
1: ONE
2: CONT
4. Press the enter key. The value is set.
5. To return to the screen for selecting an item, press the back key.
Completion
Press the back key at the screen for selecting an item. The screen for selecting a maintenance item No. is
displayed.
U625
Setting the trasmission system
Description
Makes settings for the auto redialing interval and the number of times of auto redialing.
Purpose
Change the setting to prevent the following problems: fax transmission is not possible due to too short redial
interval, or fax transmission takes too much time to complete due to too long redial interval.
Start
1. Press the enter key.
2. Select the item to be set using the up/down cursor keys.
Display
1:INTERVAL
2:TIMES

Setting the auto redialing interval

1. Change the setting using the left/right cursor keys.
Description
Redialing interval
2. Press the enter key. The value is set.

Setting the number of times of auto redialing

1. Change the setting using the left/right cursor keys.
Description
Number of redialing
When set to 0, no redialing is performed.
2. Press the enter key. The value is set.
Completion
Press the back key. The screen for selecting a maintenance item No. is displayed.
1-3-10
Description
Description
One-shot detection
Continuous detection
Description
Sets the auto redialing interval.
Sets the number of times of auto redialing.
Setting range
1 to 9 (min.)
Setting range
0 to 9