Removing The Power Supply Pwb And High Voltage Pwb - Kyocera KM-1820 Service Manual

Includes: fax system (k)
Hide thumbs Also See for KM-1820:
Table of Contents

Advertisement

2GM

(3) Removing the power supply PWB and high voltage PWB

1. Remove the process unit (see page 1-6-2).
2. Remove the left cover (see page 1-6-4).
3. Remove three connectors from the power supply PWB.
4. Remove eight screws.
5. Remove the power supply PWB and high voltage PWB. (Note: The high voltage PWB is directly connected to the
bias PWB.)
6. Separate the high voltage PWB from the power supply PWB.
Power supply
Screws
Figure 1-6-15 Removing the power supply PWB and high voltage PWB
1-6-12
PWB
Connectors
Bias PWB
High voltage
PWB
Screws