8.1.22 Replacing the gas control valve
DANGER
Work on gas pipes and fittings must only be carried
out by a registered service provider.
Switch off the power supply of the heating system on the circuit
breaker.
Set the main switch on the BC10 to "0" (Off).
Remove the casing.
Close the gas shut-off valve (see fig. 41, pos. 1).
Remove the cable plug from the gas control valve (see fig. 42,
pos. 1).
Logamax plus GB142-24/30/45/60 - We reserve the right to make any changes due to technical modifications!
fig. 40
Testing the resistance on the gas burner ass'y (2)
fig. 41
Gas shut-off valve closed (1), gas shut-off valve
open (2)
fig. 42
Removing the gas control valve plug
Actions
8
101