Xii. Operation (continued)
E.
Adjusting Parameters (continued)
Pump
"Press"
button to access the following parameters:
Setup
Factory Setting
Any Demand
Central heat, No Priority,
Central Heat, Optional Priority
Any Demand
Central heat, off DHW demand
Primary
Loop Pipe
Primary Loop Piped IWH,
IWH
Refer to "Example Pump Parameter selections:' on the next pages for additional pump setup information.
Contractor
button to access the following parameters:
"
Press
Setup
"
Factory Setting
Contractor Name
Address
Phone
10
Range / Choices
System Pump run pump for:
Activates the system pump output according to selected function.
Never:
Any Demand:
Never,
Central Heat, No Priority:
Any Demand,
Central heat, Optional Priority:
Boiler Pump run pump for:
Activates the boiler pump output according to selected function.
Any Demand:
Any Demand,
Central heat, off DHW demand: Pump Runs during central heat and frost protection call
Domestic Pump run pump for:
Activates the Domestic pump output according to selected function
Never:
Primary Loop Piped IWH:
Never,
Boiler Piped IWH:
Boiler Piped IWH
Range / Choices
User defined
User defined
User defined
Parameter and Description
Pump is disabled and not shown on status screen.
Pump Runs during any call for heat.
Pump Runs during central heat and frost protection
call for heat. Pump does not start for a DHW call for
heat and continues to run during Domestic Hot Water
Priority.
Pump Runs during central heat and frost protection call
for heat. Pump does not start for a DHW call for heat
and will be forced off if there is a DHW call for heat and
Domestic Hot Water Priority is active.
Pump Runs during any call for heat.
for heat. Pump does not start for a DHW call for heat
and will be forced off if there is a DHW call for heat and
Domestic Hot Water Priority is active.
Pump is disabled and not shown on status screen.
Pump Runs during domestic hot water call for heat.
Domestic Hot Water Priority enable/disable does not
affect pump operation.
Pump Runs during domestic hot water call for heat.
Pump is forced off during a central heat call for heat
when Domestic Hot Water Priority "disabled" is
selected and when Domestic Hot Water Priority
"enable" has been selected and the DWH call for heat
has remained on for longer than 1 hour (priority
protection time).
Parameter and Description
Contractor Name
Contractor Address
Contractor Phone