Chapter 13—Interfaces
13.1 RS-232 Serial Interface
Description
86
The RS-232 serial interface is a bidirectional communication protocol
for distances up to 10 to 15 metres (33 to 49 ft). The communication
parameters can be set in the Setup Mode (see EasyCoder PD4, User's Guide)
or using a Y command (see ESim for EasyCoder PD4 v5.xx, Programmer's
Reference Manual) as follows:
Baud rate
4,800 bps
9,600 bps
19,200 bps
38,400 bps
Parity
No parity
Odd parity
Even parity
Data length
7 bits
8 bits
Stop bit(s)
1 bit
2 bits
Handshaking is XON/XOFF and RTS/CTS
One line contains +5 VDC, max 500mA (permanently enabled)
The connector on the printer's rear plate is a DB-9pin socket.
Signals
Pin
Signal
1
2
TXD
3
RXD
4
5
GND
6
7
CTS
8
RTS
9
Meaning
Remark
External +5 VDC
Max. 500mA, permanently enabled
Transmit data
Receive data
Not used
Ground
Not used
Clear to send
Request to send
Not used