Electrical; Ambient; Plumbing; Ventilation And Service Clearances - Follett Symphony 25CI400A Installation, Operation And Service Manual

Ice and water dispensers
Hide thumbs Also See for Symphony 25CI400A:
Table of Contents

Advertisement

Electrical

115 V, 60 Hz, 1 phase, 14.0A. Connect to dedicated 20A circuit, fuse or breaker.
Note: It is preferred that circuit be protected by a GFCI.
Furnished with 7 ft (2 m) power cord with a 90° NEMA hospital grade 5-20 plug.

Ambient

Air temp
Water temp
Water pressure

Plumbing

Dispenser drain
Water inlet
Condenser inlet
Condenser outlet
Note: Water shut-off recommended within 10' (3 m) of dispenser. Drain to be hard-piped and
insulated. Maintain at least 1/4" per foot (20 mm per 1 m run) of slope on horizontal runs.
• Do not block left side air intake or right side air exhaust

Ventilation and service clearances

Required for ventilation
Suggested for service

Uncrated weight

25/50CI400A/W (countertop)
25/50HI400A (wall mount)
25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A
Maximum
100 F/38 C (Best performance below 80 F/27 C)
90 F/32 C (Best performance below 70 F/21 C)
70 psi (483 kpa)
Connections – 25/50CI400A/W
All – 3/4" FNPT
All – 3/8" FNPT
Water-cooled – 3/8" FNPT
Water-cooled – 3/8" FNPT
CAUTION
Air-cooled
3" (77 mm) each side
12" (30.5 cm) top,
6"(15.3 cm) left side
215 lbs (98 kg)
230 lbs (105 kg)
Minimum
50 F/10 C
40 F/4 C
10 psi (69 kpa)
Rough-ins – 25/50HI400A/
Air-cooled – 3/4" FNPT
All – 1/2" FNPT
N/A
N/A
Water-cooled
N/A
12" (30.5 cm) top
5