Ice machine removal

To reduce risk of shock disconnect power before
servicing.
Fig. 16– All models
1. Remove front cover (Fig. 16).
Fig. 17 – All models
2. Remove splash panel (Fig. 17).
16
WARNING
!
Fig. 18 – All models
18.1
3. Lower drain pan protector (Fig. 18.1). Remove and
discard shipping screw (Fig. 18.2).
Fig. 19 – All models
19.1
19.2
4. Close main water shut off valve (Fig. 19.1).
5. Disconnect water line to fl oat valve (Fig. 19.2).
6. Disconnect water line to solenoid (Fig. 19.3).
7. Remove screws securing bottom of ice machine
electrical box (Fig. 19.4).
25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A
18.2
19.4
19.3