SmartCombi
4.12 Changing standard settings
Requirements
4.12.1 Set service interval water volume
Global Foodservice Solutions
™
NOTICE
The end-of-step signal is activated as default for the last cooking step
of a program.
1. Press the left s e le c t bu t t o n (1 3 ) when entering a cooking
program.
2. Select the end-of-step signal with C o m b i Di a l ( 9 ) .
3. Press the left s e le c t bu t t o n ( 1 3 ) to return to the settings menu.
Unit is switched on
1. Press the left s e le c t bu t t o n ( 1 3 ) to open the menu.
2. Use C o mb iDia l (9 ) to select the "Settings" menu.
3. Use C o mb iDia l (9 ) to enter the password "111".
4. Press S t a r t / St o p ( 8 ).
5. Select the parameter with C o m b i Di a l ( 9 ) .
The multi-function display (4) shows the set value.
The parameter name flashes.
6. Press C o m b i Di a l ( 9 ) , to change the value.
The parameter value flashes.
7. Change the value with C o m b i Di a l ( 9 ) .
8. Press the right s e l e c t bu t t o n (6 ) or Co mb i Di a l (9 ) to adopt
the value.
The parameter name flashes.
9. Change other parameters as necessary.
10. Press the right s e l e c t bu t t o n ( 6 ) to save the changes.
or
→ Press the left s e le c t bu t t o n (1 3 ) to discard the changes.
In the "Settings" menu, you can specify the service interval by means
of the volume of used water.
1. Press the left s e le c t bu t t o n (1 3 ) to open the menu.
2. Use Co mb iDia l (9 ) to select the "Settings" menu.
Operating manual
Operation
57