Cleaning

5.4.1 Removing the ventilation plate (table top models)

5.4.2 Removing the ventilation plate (floor standing units)

Requirements
72
5. Examine the chamber for scale residues. Repeat decalcification if
necessary.
6. Open the chamber door and leave it slightly ajar until the next use.
This will increase the life of the door seal.
No moisture will build up in the cooking chamber.

5.4 Removing the ventilation plate

The ventilation plate can be removed for cleaning.
CAUTION
Risk of crushing fingers due to rotating fan
→ Disconnect the unit from the power supply before you remove the
ventilation plate.
→ Do not operate the unit without the ventilation plate.
1. Remove the suspension frame on the left-hand side.
2. Open the front catch.
3. Fold the ventilation plate towards the rear wall.
4. Open the rear catch.
5. Slightly raise the ventilation plate and remove it.
6. Clean the cooking chamber behind the ventilation plate.
7. Push the ventilation plate onto the upper bolts.
8. Close the rear catch.
9. Fold the ventilation plate towards the side wall.
10. Close the front catch.
11. Check the catches.
12. Replace the suspension frame on the left-hand side.
Necessary tools: box spanner
The ventilation plate can be removed for cleaning.