5.3.5 Cleaning the steam outlet port

5.3.6 Descaling

Requirements
Global Foodservice Solutions
Deposits can block the steam outlet port and the pipes connected to
it.
NOTICE
Use liquid cleaner with a maximum of 10 % soda or caustic potash
solution.
It is not necessary to rinse with water.
1. Inspect the steam outlet port and the pipes connected to it for
deposits.
2. Spray liquid cleaner in the steam outlet port.
3. With units with a condensate hood (optional), remove the
connecting pipe between the condensate hood and the steam outlet
port twice a year.
4. Spray liquid cleaner into the steam outlet port and in the opening
of the condensate hood.
5. Then replace the connecting pipe.
Cooking chamber temperature less than 40 °C (104 °F)
Cooking chamber is clean
To avoid a build-up of scale in the cooking chamber, only softened
water should be used for operation.
If hard water is used, the cooking chamber must be descaled regularly
to avoid damage to the unit.
Use Henny Penny special descaler together with a hand-held sprayer
for manual decalcification.
1. Dilute the special descaler with water at the ratio of 1:2.
2. Open the ventilation plate so that the parts behind it are moistened.
3. Spray the diluted special descaler into the cooking chamber.
4. Allow the solution 30 minutes of contact time, then rinse the
chamber thoroughly.