All plumbing work must be carried out by a qualified person and in compliance with the Standard
AS/NZS 3500.4 and all local codes and regulatory authority requirements. In New Zealand the installation
must also conform with the New Zealand Building Code.
All gas work must be carried out by a qualified person and in compliance with the Standard AS 5601 or
AS/NZS 5601.1, as applicable under local regulations, and all local codes and regulatory authority
requirements. In New Zealand the installation must also conform with NZS 5261, as applicable under local
regulations.
CONNECTION SIZES
Model
Hot water connection
Cold water connection
Gas inlet connection
WATER INLET AND OUTLET
All pipe work must be cleared of foreign matter before
connection and purged before attempting to operate the water
heater. All olive compression fittings must use brass or copper
olives. Use thread sealing tape or approved thread sealant on
all fittings.
A full flow gate valve or ball valve must be installed on the cold
water line or solar preheat water line to the water heater. A non
return valve or stop tap must not be installed. An acceptable
arrangement is shown in the diagram. Refer also to
Delivery"
on page 48 and to
A disconnection union must always be provided at the cold
water inlet and hot water outlet on the water heater to allow for
disconnection of the water heater.
Insulation used on the cold and hot water lines must extend up
to the cold water inlet and hot water outlet of the water heater.
Notes:
It is essential all pipe connections be correctly aligned, otherwise component connections within the
water heater may be strained and / or components themselves misaligned. It is recommended also,
wherever possible, pipe connections be made at the water heater first and final pipe runs be made in
soft copper pipe to allow some adjustment for misalignment.
Use the spanner flats on the water heater fittings and take care to avoid twisting the water inlet and
outlet pipes inside the jacket.
871 series in-series gas boosters with the following or a later suffix letter after the model number on the
rating label of the water heater do not need to be installed with a solar bypass valve:
018 and 020 models
024 models
026 models
The maximum supply temperature to the water heater when used as an in-series gas booster for a solar
water heater is 80°C.
CONNECTIONS – PLUMBING
871 018
871 020
-
875 018
-
R½/15
R¾/20
R½/15
R¾/20
R¾/20
R¾/20
"Mains Water Supply"
on page 47.
- B
- C
- B
871 022
-
-
-
875 022
-
-
R¾/20
R¾/20
R¾/20
"Hot Water
Cold (or Solar Preheat) and Hot Water
and Gas Connection Details
022 models
M24 models
57
871 024
871 026
871 M24
-
875 024
875 026
875 M24
R¾/20
R¾/20
R¾/20
R¾/20
R¾/20
R¾/20
Gas Water Heater
- A
- A